Notes for using Utah Scientific routers with Cablecast

Applies to

  • Cablecast 5.0.7+
  • Utah Scientific 100x routers controlled using the UtahScientificRCP1 Control Module
  • Utah Scientific 100/UDS-10 routers controlled using the UtahScientificRCP1 Control Module

Utah Scientific 100x Notes

There are several differences between the 100x series of routers and other Utah RCP-1 compliant routers:

  1. Different baud rate
    Most RCP-1 routers use 9600 baud for serial control. The 100x uses 19200.  Cablecast can be configured to use 19200 baud by setting the UtahScientificRPC1-BaudRate setting in the CablecastDeviceControl configuration file.
  2. I/O numbering starts at 1
    The first input or output on other RCP-1 routers will be labeled 0 on the back panel.  The 100x router has the first I/O labeled 1 instead.
  3. Different serial pinout
    The 100x requires a female-to-female DB9 cable wired as a null modem.  No pins other than 2, 3 and 5 should be connected.
  4. RCP-1 Protocol needs to be manually enabled. It is not enabled by default on 100x series devices.

Utah Scientific 100/UDS-10 Notes

Please note the following differences when configuring a UDS-10 router.  Once the router has been configured, you will likely notice that the Cablecast force menu doesn't get router status.  Please make the following changes to the CablecastDeviceControl configuration file to enable status reporting:

  1. UtahScientificRPC1-Outputs: set to "1,2,3,4,5,6,7,8,9,10"
  2. UtahScientificRPC1-Levels: set to "1,2,3,4,5,6,7,8"

Once these changes have been made, and the CablecastDeviceControl service has been restarted, status should work as expected.

Additional Information

The 100x series of routers is only supported in Cablecast 5.0.7 and above because the router requires a different serial baud rate than standard RCP-1 routers.  Prior to version 5.0.7, it wasn't possible to change the baud rate for this Control Module.

 

To enable the RCP-1 Protocol please use the web interface of the router.

0 (0)
Article Rating (No Votes)
Rate this article
  • Icon PDFExport to PDF
  • Icon MS-WordExport to MS Word
Attachments Attachments
There are no attachments for this article.
Related Articles RSS Feed
How to perform a system database migration
Viewed 1814 times since Thu, Jul 30, 2015
Channel Licenses for Cablecast Servers
Viewed 1344 times since Fri, Jun 26, 2015
SX Server will not validate any files but playback using SXConfiguration works
Viewed 1673 times since Wed, Sep 24, 2014
Reports in Cablecast 6.1 with Producer Breakdown field shows blank
Viewed 664 times since Fri, Sep 9, 2016
Deleting a Control Module Set (CMS) requires a browser refresh
Viewed 408 times since Thu, Nov 2, 2017
Source Incomplete VODs never progress
Viewed 1344 times since Fri, Oct 3, 2014
Locating my hardware license key
Viewed 3959 times since Wed, Sep 17, 2014
Retranscoding a VOD file in Cablecast 5.2 and above
Viewed 1455 times since Mon, Sep 22, 2014
Contact information not being saved for automatic database back ups
Viewed 1566 times since Mon, Oct 6, 2014